Table 15-1 Attack Alert

FIELD DESCRIPTION

DEFAULT

VALUES

Blocking Time When TCP Maximum Incomplete is

reached you can choose if the next
session should be allowed or blocked. If
you check Blocking Time any new
sessions will be blocked for the length of
time you specify in the next field (min) and
all old incomplete sessions will be cleared
during this period. If you want strong
security, it is better to block the
traffic for a short time, as it will give the
server some time to digest the loading.

Select this check box to specify

a number in minutes (min) text

box.

(min) Enter the length of Blocking Time in

minutes.

0

When you have finished, click Apply to save your customized settings and exit this screen, Cancel to