Fix price operation (us model only), 4 fix price operation (us model only) – Toshiba SL-5300 Series User Manual
Page 184

16. REGISTRATION MODE
EO1-31009
16.4 Fix Price Operation (US model only)
16-38
NOTE: 
To cancel the printing, touch the [CLEAR] key or [VOID] key. When one of these keys is touched, the 
following screen will appear. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Touching the [NO] key causes the printing to be cancelled and the all specified data are cleared. 
To continue to print, touch the [YES] key. 
On the Commodity Name area, the PLU under printing, the specified number of labels, and the remaining 
number of labels are displayed. 
 
 
16.4 Fix Price Operation (US model only)
This operation is intended for the commodities which total prices are fixed. 
 
1. Call the PLU. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. Set the tare. This is not necessary when a container is not used or when the tare is preset to the 
PLU. However, the preset tare function is not available with the initial settings. When you desire 
to use this function, please contact your nearest TOSHIBA TEC service representative or sales 
agent. 
3. When the unit price has not been set to the PLU, enter the unit price. Note that the preset unit
price cannot be changed with the initial settings. When you desire to make the preset unit price 
changeable, contact your nearest TOSHIBA TEC service representative or sales agent. 
Commodity name, PLU No., 
the number of specified labels, 
the remaining number of labels 
NO key
YES key
