16. REGISTRATION MODE
EO1-31009
16.2 Basic Operations
16-18
16.2.3 Weighing Commodities and Issuing Labels
1. Confirm that the scale mode is in the WEIGH mode.
NOTE: To set the scale mode to the WEIGH mode, refer to Section 16.1.3 Mode Change.
2. Touch and select the label issue method, the AUTO or MANUAL.
NOTE: The label issue method can be also selected in Section 16.1.3. Mode Change.
3. Refer to Section 16.2.4, and enter the tare. (This is not necessary when the tare has been preset
to the PLU.)
4. Call the PLU.
5. Refer to Section 16.2.7, and enter the unit price. (This is not necessary when the unit price has
been preset to the PLU.)
6. Place the commodity on the platter.
7. When the label issue method is AUTO, a label will be issued automatically.
When the label issue method is MANUAL, touch the [PRT/*] key to issue a label.
NOTE: When the commodity is removed from the platter, the called PLU data is cleared. It may be a little
troublesome to call the PLU each time, especially when weighing the same commodities of
different weight and issuing their labels repeatedly. In this case, touching the [SAVE] key after the
PLU, Tare, and Unit Price are called or entered, will cause the data to be retained even after the
commodity is removed from the platter. In this state, “PREPACK” is displayed on the Tare area
and Unit Price area.
AUTO
WEIGH MANUAL
WEIGH
AUTO/MANUAL key
PRT/* key
PREPACK