F8: midi – Yamaha PSR-4000 User Manual
Page 121
![background image](/manuals/20944/121/background.png)
117
F8: MIDI
■
CLOCK & TRANSPOSE
.........................................................................................................................................................
●
CLOCK
Determines whether the PSR-4000 is controlled
by its own internal clock or a MIDI clock signal
received from an external device.
INTERNAL is the
normal
CLOCK setting when the PSR-4000 is being
used alone. If you are using the PSR-4000 with an
external sequencer, MIDI computer, or other MIDI
device, and you want the PSR-4000 to be synchro-
nized to the external device, set this function to
EXTERNAL. In the latter case, the external device
must be connected to the PSR-4000 MIDI IN con-
nector, and must be transmitting an appropriate
MIDI clock signal.
●
TRANSPOSE
When the
TRANSPOSE TRANSMIT parameter
is turned
OFF, the PSR-4000 transpose settings are
not applied to transmitted MIDI data. When turned
ON, the PSR-4000 transpose settings apply to trans-
mitted MIDI data in the same they do to notes played
on the PSR-4000 itself. When the
TRANSPOSE
RECEIVE parameter is turned OFF note data re-
ceived by the PSR-4000 is not transposed, and when
set to
ON the received note data is transposed ac-
cording to the current PSR-4000 transpose setting.
A check mark appears in the
TRANSPOSE TRANS-
MIT or RECEIVE box when the corresponding
parameter is
ON.
■
MESSAGE SWITCH
...................................................................................................................................................................
●
START/STOP
The
START/STOP TRANSMIT parameter turns
MIDI transmission of MIDI start and stop com-
mands corresponding to starting or stopping the
PSR-4000 accompaniment or song play/record func-
tions
ON or OFF. The START/STOP RECEIVE
parameter turns MIDI reception of MIDI start and
stop commands generated by external equipment
ON or OFF. A check mark appears in the MESSAGE
SW START/STOP TRANSMIT or RECEIVE box
when the corresponding parameter is
ON.