beautypg.com

F8: midi – Yamaha PSR-4000 User Manual

Page 121

background image

117

F8: MIDI

CLOCK & TRANSPOSE

.........................................................................................................................................................

CLOCK

Determines whether the PSR-4000 is controlled

by its own internal clock or a MIDI clock signal
received from an external device.

INTERNAL is the

normal

CLOCK setting when the PSR-4000 is being

used alone. If you are using the PSR-4000 with an
external sequencer, MIDI computer, or other MIDI
device, and you want the PSR-4000 to be synchro-
nized to the external device, set this function to
EXTERNAL. In the latter case, the external device
must be connected to the PSR-4000 MIDI IN con-
nector, and must be transmitting an appropriate
MIDI clock signal.

TRANSPOSE

When the

TRANSPOSE TRANSMIT parameter

is turned

OFF, the PSR-4000 transpose settings are

not applied to transmitted MIDI data. When turned
ON, the PSR-4000 transpose settings apply to trans-
mitted MIDI data in the same they do to notes played
on the PSR-4000 itself. When the

TRANSPOSE

RECEIVE parameter is turned OFF note data re-
ceived by the PSR-4000 is not transposed, and when
set to

ON the received note data is transposed ac-

cording to the current PSR-4000 transpose setting.
A check mark appears in the

TRANSPOSE TRANS-

MIT or RECEIVE box when the corresponding
parameter is

ON.

MESSAGE SWITCH

...................................................................................................................................................................

START/STOP

The

START/STOP TRANSMIT parameter turns

MIDI transmission of MIDI start and stop com-
mands corresponding to starting or stopping the
PSR-4000 accompaniment or song play/record func-
tions

ON or OFF. The START/STOP RECEIVE

parameter turns MIDI reception of MIDI start and
stop commands generated by external equipment
ON or OFF. A check mark appears in the MESSAGE
SW START/STOP TRANSMIT or RECEIVE box
when the corresponding parameter is

ON.