Command Parameters T

able

Cmd

ID

Description

on LCD

Brief Description

Location Map

Example

Rqd Security Level to change

By

Tab

Block

658

e

n

r

estart

e

nable

r

estart

- Non-volatile configuration.

After shutdown by

battery

, U

p

S will restart if input power recover

.

d

efault from factory is

e

nable.

Settings

C&C

e

nable

n

onchangeable

Changeable

User

Administrator

659

r

estart

d

elay

r

estart

d

elay

Settings

C&C

10 Sec

n

onchangeable

Changeable

User

Administrator

660

e

n

AutoXfer

e

nable

Auto

transfer

- Non-volatile configuration. Enable auto transfer when current limit occurs.

it will switch

bypass and

o

n-

line mode.

Settings

C&C

e

nable

n

onchangeable

Changeable

User

Administrator

662

AutoXfer

w

in

-

dow

Auto

transfer

time

w

indow

- Non-volatile configuration. Default from fac

-

tory is 3 Seconds.

Settings

C&C

3 Sec

n

onchangeable

Changeable

User

Administrator

663

Srv

p

ort

b

aud*

Service

p

ort

b

aud

r

ate

- Non-volatile configuration. Default from fac

-

tory is 57600.

Settings

C&C

57600

n

onchangeable

Changeable

User

Administrator

682

Special

p

urpose

(Call Factory for Further

information)

Settings

C&C

n

onchangeable

n

onchangeable

User

Administrator

693

invert

r

mt

S

d

own

r

emoted Shutdown

inverted

logic

- Non-volatile configuration. Default from fac

-

tory is

n

ormally

o

pen

Settings

C&C

n

ormally

o

pen

n

onchangeable

Changeable

User

Administrator

695

r

estart

m

ode*

r

estart U

p

S

m

ode

- Non-volatile configuration. Default from fac

-

tory is

o

n-

line

Settings

C&C

o

n-

line

n

onchangeable

Changeable

User

Administrator

697

Special

p

urpose

(Call Factory for Further

information)

Settings

C&C

n

onchangeable

n

onchangeable

User

Administrator

701

System

o

p

time

total System

o

peration

time

- n

on-volatile history record.

d

efault from fac

-

tory is zero.

Settings

H

iS

t

123 Sec

n

onchangeable

n

onchangeable

User

Administrator

702

inverter

o

p

time

total

inverter

o

peration

time

- n

on-volatile history record.

d

efault from fac

-

tory is zero.

Settings

H

iS

t

123 Sec

n

onchangeable

n

onchangeable

User

Administrator

703

b

ackup

o

p

time

total

b

ackup

o

peration

time

- n

on-volatile history record.

d

efault from fac

-

tory is zero.

Settings

H

iS

t

123 Sec

n

onchangeable

n

onchangeable

User

Administrator