beautypg.com

Toshiba UNINTERRUPTIBLE POWER SYSTEM 1600XP User Manual

Page 59

background image

51

1600Xp Series installation and operation manual

1600

xP

Command Parameters T

able

Cmd

ID

Description

on LCD

Brief Description

Location Map

Example

Rqd Security Level to change

By

Tab

Block

303

b

ypass V

oltage

b

ypass V

oltage

- p

resent calculated bypass voltage

m

onitor

byp

240 V

n

onchangeable

n

onchangeable

User

Administrator

304

b

ypass Current

b

ypass Current

- U

p

S presently calculated bypass current

m

onitor

byp

25.0

A

n

onchangeable

n

onchangeable

User

Administrator

305

b

ypass Fre

-

quency

b

ypass Frequency

- U

p

S presently calculated bypass frequency

m

onitor

byp

60.0 Hz

n

onchangeable

n

onchangeable

User

Administrator

307

b

ypass

p

ower(V

A)

b

ypass

Apparent

p

ower

- U

p

S presently calculated bypass apparent

power

.

m

onitor

byp

6000 V

A

n

onchangeable

n

onchangeable

User

Administrator

315

V

b

ypUV

d

e-

level*

b

ypass Undervoltage

d

etection

level -

p

er

-

centage of rated input voltage command

id

11

1.

Setting

byp

62 %

n

onchangeable

n

onchangeable

User

Administrator

316

V

b

ypUV

r

el

evel*

b

ypass Undervoltage

r

ecovery

level in per

-

centage

- o

f rated input voltage command

id

1

11.

Setting

byp

66 %

n

onchangeable

n

onchangeable

User

Administrator

317

V

b

yp

o

V

d

e-

level

b

ypass

o

ver V

oltage

d

etection

level in V

olt

Setting

byp

284 V

n

onchangeable

n

onchangeable

User

Administrator

318

V

b

yp

o

V

r

el

evel

b

ypass

o

ver V

oltage

r

ecovery

level in V

olt

Setting

byp

274 V

n

onchangeable

n

onchangeable

User

Administrator

401

d

C

b

us

total

d

C

b

us V

oltage

total

- Currently calculated

d

C

b

us total voltage

m

onitor

d

C

770 Vdc

n

onchangeable

n

onchangeable

User

Administrator

402

d

C

b

us

p

osi

-

tive

d

C

b

us V

oltage (+)

- U

p

S presently calculated

d

C

b

us positive

voltage

m

onitor

d

C

385 Vdc

n

onchangeable

n

onchangeable

User

Administrator

403

d

C

b

us

n

ega

-

tive

d

C

b

us V

oltage (-)

- U

p

S presently calculated

d

C

b

us negative

voltage

m

onitor

d

C

385 Vdc

n

onchangeable

n

onchangeable

User

Administrator

404

r

ated

d

C

b

us*

r

ated

d

C

b

us V

oltage

- Used to calculated percentage.

Setting

d

C

770 Vdc

n

onchangeable

n

onchangeable

User

Administrator

501

b

attery V

oltage

Charger or

b

attery V

oltage

- U

p

S calculates and shows current charger

voltage during charging or battery voltage dur

-

ing

b

ackup

m

onitor

b

Att

234 Vdc

n

onchangeable

n

onchangeable

User

Administrator