Toshiba UNINTERRUPTIBLE POWER SYSTEM 1600XP User Manual

Page 57

background image

49

1600Xp Series installation and operation manual

1600

xP

Command Parameters T

able

Cmd

ID

Description

on LCD

Brief Description

Location Map

Example

Rqd Security Level to change

By

Tab

Block

136

input Cur

-

rent(%)

input Current

p

ercentage

m

onitor

in

100 %

n

onchangeable

n

onchangeable

User

Administrator

137

V

iUV

d

el

evel

input Undervoltage

d

etection

- Calculated according to load and adjusted by itself.

m

onitor

in

190 V

n

onchangeable

n

onchangeable

User

Administrator

138

V

iUV

r

el

evel

input Undervoltage

r

ecovery

- Calculated according to load and adjusted by itself.

m

onitor

in

200 V

n

onchangeable

n

onchangeable

User

Administrator

139

r

ated

in

p

ower(

w

)

r

ated

input

p

ower in

w

att

- Calculated from typeform command

id

002.

m

onitor

in

6000

w

n

onchangeable

n

onchangeable

User

Administrator

141

Freq on F

i-

err

*

Freq setup on input frequency error

- t

oshiba U

p

S try to detect input frequency but

very tiny percentage when U

p

S can not detect

the input frequency because of fluctuation, 1600X

p U

p

S will start by using this setup.

Setting

in

60.0 Hz

n

onchangeable

Changeable

User

Administrator

201

Output Config

Output Configuration

- d

isplays the voltage and frequency

240 V 60 Hz, or 208 V 60 Hz

m

onitor

o

U

t

240V - 60Hz

n

onchangeable

n

onchangeable

User

Administrator

202

n

o of

o

utput

line

n

o of

o

utput

lines

- Always 1 input line for 1600X

p series

Setting

o

U

t

1

line

n

onchangeable

n

onchangeable

User

Administrator

203

o

utput V

oltage

o

utput V

oltage

- U

p

S presently calculated output voltage

m

onitor

o

U

t

240 V

n

onchangeable

n

onchangeable

User

Administrator

204

o

utput Current

o

utput Current

- U

p

S presently calculated output current

m

onitor

o

U

t

25.0

A

n

onchangeable

n

onchangeable

User

Administrator

205

o

utput Fre

-

quency

o

utput Frequency

- U

p

S presently calculated output frequency

m

onitor

o

U

t

60.0 Hz

n

onchangeable

n

onchangeable

User

Administrator

206

o

utput

p

ower(

w

)

o

utput

Active

p

ower

- U

p

S presently calculated output active power

.

if U

p

S can not calculate for output active

power

, display shows

n

/A.

e

specially

, bypass

and shutdown

m

onitor

o

U

t

5100

w

n

onchangeable

n

onchangeable

User

Administrator

207

o

utput

p

ower(V

A)

o

utput

Apparent

p

ower

- U

p

S presently calculated output apparent

power

.

m

onitor

o

U

t

6000 V

A

n

onchangeable

n

onchangeable

User

Administrator