Preparation for Installation 4-30

II

L

00

16) Connect the CST AC cable coming from the Container Stacker to the J236 on the power

supply of the printer (Connection 1 on the below figure). At this time, connect CE AC cable that
is disconnected from the J236 to the connector of the CST AC cable (Connection 2 on the
below figure)

17) Mount the CST FG cable coming from Container Stacker side on the printer frame by using

M4 screw (Connection 3 on the below figure).

18) Install the CPXXX P/K on the CP P/K holder, and then install it with OC P/K ass’y in the

Engine.

19) Connect FNS IF cable of 20 pin black connector coming from the printer to the J680

connector of ST09X P/K board in Container Stacker (Connection 4 on the below figure).

(Do not use the 4 pin white connector Disconnection 2 on the below figure).
20) Disconnect the 4 pin white connector of the DC IF cable of the printer from the FNS IF cable

(Disconnection 1 on the below figure). Then connect it to the RB cable of 4 pin white connector
coming from Container Stacker. (Connection 5 on the below figure)

[Note] Put the cable through the opening “A” of the Engine for connection.

Details of Connection 1 and Connection2.

CTS AC cable

CE AC cable

Opening “A”

PS

DC IF cable

RB cable

FNS IF cable

M4 screw

(Connection 3)

PS

Engine

Container

CST FG cable

Connection 1

Connection 2

Connection 4
(20 pin black)

Disconnection 2

(4 pin white)

Connection 5

(4 pin white)

Disconnection 1

(4 pin white)

Disconnection 3

(2 pin white)

J236

CST AC Cable

CE AC Cable

Connector : 2 pin white

Connector : 2 pin white

PS

II

L

01

[RoHS Compliance Unit]

[No RoHS Compliance Unit]

8

7

6

5

4

2
3

1

M

K

K

O

N

O

F

F

O

F

F

S

W
1

8

7

6

5

4

2
3

1

M

K

K

O

N

O

F

F

O

F

F

S

W
2