Figure 51, Table 42 – Nortel Networks 380-24F User Manual
Page 118

118
Chapter 7 Configuring application settings
214394-A
To configure port mirroring:
1
From the main menu, choose Application > Port Mirroring.
The Port Mirroring page opens
Figure 51 Port Mirroring page
describes the items on the Port Mirroring page.
Table 42 Port Mirroring page items
Item Range
Description
Monitoring Mode
(1) Disabled
(2) --> Port X
(3) Port X -->
The default setting is Disabled.
Monitor Port
1..12
13..24
Choose the switch port to designate as the monitor port.
Port X
1..24
13..24
Choose the switch port to be monitored by the designated
monitor port. This port is monitored according to the value “X”
in the Monitoring Mode field.