Customizing the VSX System
4 - 29
Configuring RS-232 Equipment
The VSX 5000, VSX 6000, VSX 6000A, VSX 7000, and VSX 7000s systems
provide one RS-232 port; the VSX 7000e and VSX 8000 systems provide two.
1.
Go to System > Admin Settings > General Settings > Serial Port.
2.
Configure these settings:
Configuring for Use with a Touch Panel Control
VSX systems that have a serial port can be configured for use with a touch
panel control.
To configure the serial port for a touch panel:
1.
Go to System > Admin Settings > General Settings > Serial Port.
2.
Configure these settings:
Setting
Description
Baud Rate
Set the baud rate to the same value that it is set on the
serial device.
RS-232 Mode
Specifies the mode used for the serial port. Available
settings depend on the VSX system model.
•
Control—Receives control signals from a touch-panel
control.
•
Sony PTZ—Provides control signals to a PTZ camera.
(VSX 7000, VSX 7000s, VSX 7000e, VSX 8000)
•
Closed Caption—Receives closed captions from a
captioning service using a modem, or directly from a
captioner’s computer via Telnet.
•
Vortex Mixer—Provides control signals to a Polycom
Vortex mixer.
•
Pass Thru—Passes data to an RS-232 device
connected to the serial port of the far-site system.
•
Polycom Annotation—Provides control signals to the
Polycom Instructor RP™.
•
Debug—Provides a Telnet trace for debugging. You
can only set one RS-232 port at a time to Debug mode.
Setting
Description
Baud Rate
Set the baud rate to the same value that it is set on the
touch panel control.
RS-232 Mode
Select Control. This allows any device connected to the
RS-232 port to control the system using API commands.