Options, Examples, Factorydefaults – Promise Technology Network Device EX8654 User Manual
Page 214: Usage, Summary

SuperTrak EX Series User Manual
200
Options
-t
Specifies the type of file to export.
userdb
User database file. This file type is not applicable for in-
band and can only be exported to a remote host.
servicereport
System service report file. This file is exported to remote
host for embedded and local host for in-band.
-f
Specifies the name of the file to be exported.
-s
Specifies TFTP server’s IP or host name.
Do not specify TFTP server for in-band.
-p
The port number of the TFTP server. Default is 69.
Do not specify port number for in-band.
Examples
export -t userdb -s 192.168.1.1 -f userdb.bin
export -t servicereport -s 192.168.1.1 -f servicereport # for embedded
export -t servicereport -f servicereport # for in-band
factorydefaults
Usage
factorydefaults -a
Summary
The factorydefaults command restores factory default settings.
Options
-a
Specifies the action to perform.
restore
Restore the factory default settings.
-t
Specifies the type of settings to restore.
all
All settings.
allfw
All firmware settings.
allsw
Subsystems only. All software settings.
Following are individual Firmware settings:
bga
Background activity settings.
ctrl
Controller settings.
encl
Enclosure settings, including temperature thresholds,
buzzer etc.
fc
Subsystems only. FC port settings.