Examples, Event, Usage – Promise Technology Network Device EX8654 User Manual
Page 212

SuperTrak EX Series User Manual
198
mod
Modifies settings. Requires the -s option.
locate
Locates an enclosure by flashing its LEDs.
-e
Enclosure ID. The default value is 1 if unspecified.
For list action, the default is for all enclosures if
unspecified.
-s "
tempwarning=
Enclosure warning theshold temperature, in degrees
Celsius.
10..51
tempcritical=
Enclosure critical theshold temperature, in degrees
Celsius.
52..61
ctrltempwarning= Controller warning theshold temperature, in degrees
Celsius.
10..61
ctrltempcritical=
Controller critical threshold temperature, in degrees
Celsius.
62..71
-t
Specifies which type of FRU to locate. Requires -a locate
option.
ctrl
Locates the controller.
cooling
Locates the cooling unit. Only works with SAS type
enclosure.
psu
Locates the power supply unit. Only works with SAS type
enclosure.
-f
Specifies id of FRU to locate. Requires -a locate option.
Valid values are 1 and 2.
-v
Verbose mode. Requires -a list option. VPD information
is displayed.
Examples
enclosure
enclosure -v
enclosure -a mod -s "tempwarning=40,tempcritical=55"
event
Usage
event [-a