beautypg.com

Paradyne 3800 User Manual

Page 75

background image

COMSPHERE 3800 Series Modems – Model 3830

4-40

November 1996

3830-A2-GB91-20

Table 4-3

(12 of 15)

Model 3830 S-Registers

S78

V.32 bis Automode (Dial Line)

If enabled, automode permits the modem to automatically connect to a
remote modem using any supported modulation scheme.

If disabled, the modem only supports the modulation scheme selected by
the S41 register (Dial-Line Rate).

If the modem is in a modem pool attached to a System 85 Private Branch
Exchange (PBX), S78 should be set to 2. This modifies parameters used
during connection to the PBX.

Register has the following values:

0 = Enable
1 = Disable
2 = System 85

Factory setting is Enable.

S80

No Data Disconnect Trigger Signal

Register determines whether Pin 2 (transmit data) or Pin 3 (receive data)
of the modem’s RS-232 serial interface is monitored so that the modem
can disconnect the call if there is no activity for a certain period. (See the
\T command.)

Register has the following values:

0 = Transmit or Receive
1 = Transmit only
2 = Receive only
3 = Transmit and Receive

Factory setting is 3.