background image

4. AT Command Set and S-Registers

4-35

3830-A2-GB91-20

November 1996

Table 4-3

(7 of 15)

Model 3830 S-Registers

S48

Leased Line Carrier On Level

Determines if the modem disconnects if the carrier signal on leased lines
falls below –26 dBm or –43 dBm.

Register has the following values:
0 = –43 dBm
1 = –26 dBm

Factory setting is –43 dBm.

S49

Transmit Buffer Disconnect Delay

Determines the maximum amount of time the modem can continue to
send data in its Transmit Buffer to the remote modem after it is
commanded by the DTE to disconnect.

Register has the following values:

0 = Disable (Immediate disconnect)
1 = 1 second
2 = 2 seconds

D

D

D

D

255 = 255 seconds

Factory default is 10 seconds.

S51

DTE Remote Loopback (CT140)

Determines if the modem performs a remote digital loopback if it receives
a CT140 signal from the DTE.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.