Paradyne 3800 User Manual

Page 71

background image

COMSPHERE 3800 Series Modems – Model 3830

4-36

November 1996

3830-A2-GB91-20

Table 4-3

(8 of 15)

Model 3830 S-Registers

S52

DTE Local Loopback (CT141)

Determines if the modem performs a local analog loopback if it receives a
CT141 signal from the DTE.

Register has the following values:

0 = Disable
1 = Enable

Factory setting is Disable.

S55

Access from Remote

Determines whether the 3830 modem’s configuration options can be
accessed by a remote 3800 Series modem via a dial-line or leased-line
connection.

0 = Enable
1 = Disable

Factory default is Enable.

S61

CT111 Rate Control

Determines if CT111 Rate is disabled, set for Fallback 1 or Fallback 2.

CT111 Rate allows the DTE to control modem rate via Pin 23 of the
EIA-232-D interface. This configuration option determines the effect of the
DTE Rate Control signal. It is only valid in Async Direct mode and
Synchronous mode. For proper operation, disable the V32 bis Autorate
(S76) and V32 bis Automode (S78) configuration options.

Register has the following values:

0 = Disable
1 = Fallback 1
2 = Fallback 2

Factory setting is Disable