beautypg.com

Paradyne 3800 User Manual

Page 58

background image

4. AT Command Set and S-Registers

4-23

3830-A2-GB91-20

November 1996

Table 4-2

(17 of 22)

Model 3830 AT Commands

&Z

n =x

Store Telephone Numbers

Modem saves the telephone number and dial command modifiers (if any)
entered for

x (up to 40 characters in length) in Directory Location n

(1–10). The DS command dials numbers stored this way.

For example, the command AT&Z1=5551234 stores the telephone
number 555 –1234 into directory location 1.

To clear a telephone number from a memory location, issue the &Z

n

command without entering a telephone number.

\A

n

Maximum Frame Size

Sets the maximum frame size for V.42 and MNP. For V.42, 128 is the
maximum value; if a larger value is specified, it will default to 128. For
MNP, the minimum value is 64; if a smaller value is specified, it will
default to 64.

\A0

64

\A1

128

\A2

192

\A3

256

\A4

32

\A5

16

&F5 sets this to \A4.