4. AT Command Set and S-Registers

4-31

3830-A2-GB91-20

November 1996

Table 4-3

(3 of 15)

Model 3830 S-Registers

S12

Escape Guard Time

Sets the value (in 20-millisecond increments) for the required pause
before and after the escape sequence is issued. The guard time prevents
the modem from interpreting data as the escape sequence characters.

Enter a value from 0–255 in 20-millisecond increments. For example, the
factory setting of 50 equals 1000 milliseconds or one second. Factory
setting is 50 (1 second).

S18

Test Timeout

Sets the duration (in seconds) for the modem tests. This automatically
cancels any test in progress after the time of this register expires. Any
test can be manually canceled by issuing the escape sequence (+++)
followed by the &T0 command.

Enter a value from 0–255 seconds. (A value of 0 disables this register.)

Factory setting is Disable (0).

S26

RTS-to-CTS Delay

Sets the length of time (in 10-millisecond increments) the modem waits
after receiving RTS before issuing CTS to the DTE.

Enter a value from 0–255.

Factory setting is 0 milliseconds.