Paradyne 3800 User Manual
Page 61
COMSPHERE 3800 Series Modems – Model 3830
4-26
November 1996
3830-A2-GB91-20
Table 4-2
(20 of 22)
Model 3830 AT Commands
N
n
Error Control Mode
Determines the type of error control used by the modem. In most cases,
V42/MNPorBfr is the best choice. If V.42 bis and MNP are enabled, then
the modem uses the following priority for error control negotiation:
V.42 bis, V.42, MNP 5 and below. Online changes do not take effect until
a disconnect occurs.
\ N0 Buffer Mode.
\ N1 Direct Mode.
\ N2 MNP or Disconnect.
\ N3 MNP or Buffer.
\ N4 V.42/MNP or Disconnect.
\ N5 V.42/MNP or Buffer.
&F5 and &F6 (Cellular) set this to \N4.
\Qn
Flow Control of DTE, Flow Control of Modem
The \Q
n command controls two configuration options simultaneously:
Flow Control Flow Control
of DTE of Modem
\Q0 Disable
Disable
\Q1 XON/XOFF
XON/XOFF
\Q2 CTS to DTE
Disable
\Q3 CTS to DTE
RTS to Modem
\Q4 XON/XOFF
Disable
\Q5 Disable
XON/XOFF
\Q6 Disable
RTS to Modem
FLOW CONTROL OF DTE
Determines how the modem controls the flow of data from the DTE.
FLOW CONTROL OF MODEM
Determines how the DTE controls the flow of data from the modem.