beautypg.com

Paradyne 3800 User Manual

Page 68

background image

4. AT Command Set and S-Registers

4-33

3830-A2-GB91-20

November 1996

Table 4-3

(5 of 15)

Model 3830 S-Registers

S39

Receive Buffer Disconnect Delay

Determines the maximum amount of time the modem can continue to
send data in its Receive Buffer to the DTE after the modem is
commanded by the DTE to disconnect, or after the modem detects a line
disconnect.

Register has the following values:

0 = Disable (Immediate disconnect)
1 = 1 second
2 = 2 seconds

D

D

D

D

255 = 255 seconds

S41

Dial-Line Rate

Determines the modem’s highest data rate and modulation scheme for
operation on dial lines.

Register has the following values:

1 = 14,400 (V.32 bis)
2 = 12,000 (V.32 bis)
3 = 9600 (V.32 bis/V.32)
4 = 7200 (V.32 bis)
5 = 4800 (V.32 bis/V.32)
6 = 2400 (V.22 bis)
7 = 1200 (V.22)
8 = 1200 (212A)
10 = 0–300 (V21)
11 = 0–300 (103J)
12 = 1200/75 (V.23)
13 = 75/1200 (V.23)
20 = 19,200 (V.32

terbo)

21 = 16,800 (V.32

terbo)

Factory setting is 19,200 (V.32

terbo).