Paradyne 3800 User Manual
Page 52

4. AT Command Set and S-Registers
4-17
3830-A2-GB91-20
November 1996
Table 4-2
(11 of 22)
Model 3830 AT Commands
&
I
n
Dial Transmit Level for Cellular Auto
When Dial Transmit Level Type is set to Permissive, &
In
sets Dial
Transmit Level to a value between –10 and –32 dBm. &
I
99 and &
I
100
causes the level to be varied automatically according to conditions for
Enhanced Throughput Cellular (ETC) operation. &J0 overrides this
command.
&
I
10 –10 dBm
&
I
11 –11 dBm
D
D
D
D
&
I
32 –32 dBm
&
I
99 Automatically adjusted according to the ETC1.0 specification. Use
only with remote modems set to &
I
99, and limit the data rate to 4800 bps
(S41=5).
&
I
100 Automatically adjusted according to the ETC1.1 specification. Set
by &F6.
&J
n
Dial Transmit Type
Sets the power output level of the transmit signal over dial lines.
&J0 Permissive (–9 dBm).
&J1 Programmable.
&L
n
Leased Mode
Sets the modem for 2-wire leased-line operation in Answer mode
(receiving a call) or in Originate (initiating a call) mode.
&L0 Disables leased-line operation.
&L1 2-wire originate leased-line operation.
&L3 2-wire answer leased-line operation.
The &L command will cause the modem to reset before entering or
exiting Leased-Line mode. Therefore, it must be entered as the last
command in an initialization string.