Paradyne 3800 User Manual
Page 65
COMSPHERE 3800 Series Modems – Model 3830
4-30
November 1996
3830-A2-GB91-20
Table 4-3
(2 of 15)
Model 3830 S-Registers
S5
Backspace Character
Determines ASCII value used as the backspace (Backspace key). This
character moves the cursor to the left and erases the previous character.
Enter a value from 0–127.
Factory setting is 08 (ASCII backspace).
S6
Blind Dial Pause
Determines how long (in seconds) the modem waits after going off-hook
before dialing a telephone number if using result code X0, X1, or X3.
Enter a value from 2–255 seconds.
Factory setting is 2 seconds.
S7
No Answer Timeout
Determines how long (in seconds) an originating modem waits before
abandoning a call when no answer tone is received.
Enter a value from 1–255 seconds.
Factory setting is 45 seconds.
S8
‘‘,” Pause Time for the Dial Modifier
Determines how long (in seconds) the modem pauses when it encounters
a comma (,) in the Dial command string.
Enter a value from 0–255 seconds.
Factory setting is 2 seconds.
S10
No Carrier Disconnect
Determines how long (in tenths of seconds) the modem allows the carrier
signal to be Off before disconnecting the call.
Enter a value from 0–254 in 0.1 second increments. (A value of 255
disables this register.)
Factory setting is 20 (2 seconds).