beautypg.com

Buffer size, Number (of) buffers, Fifo trigger – Printronix L5035 User Manual

Page 95: Diagnostic, Series 1 poll

background image

Serial Parameters (RS-232 And RS-422)

95

Buffer Size

Value: 8192 bytes.

This parameter reflects the size in characters of the printer’s data
buffer.

This parameter cannot be changed in the current release of the
emulation software. However, it might be changeable in a future
release.

Number (of) Buffers

Value: 2.

This parameter reflects the number of data buffers in the printer’s
memory.

This parameter cannot be changed in the current release of the
emulation software. However, it might be changeable in a future
release.

FIFO Trigger

Values: None, 1, 4, 8, or 14 (default).

You can specify how many bytes the First In, First Out (FIFO) input
buffer stores before the bytes are sent to the printer’s data buffer.

Diagnostic

Values: None (default), Transmit, or Loopback.

This parameter provides for testing of the serial interface circuits.
Tests include a data transmission test and a serial loopback test
(which requires a loopback plug).

Series 1 Poll

Values: The allowable range is 0 through 255. The default value for
this parameter is 0.

This parameter selects the character that the printer recognizes as
the Series 1 poll character.