Chapter 3

Printer Configuration

92

SERIES 1, 2 CH

When you select the Series 1 with 2 Characters protocol, the printer
behaves exactly the same as the Series 1 with 1 Character
protocol, except that the printer sends two-character responses to
the host. These response characters are listed in the following
table:

NOTE: When using the SERIES 1, 2 CH protocol, be careful with

the transmission of binary data (control codes, bit images,
etc.) since the printer discards poll characters.

Baud Rate

Values: 110 to 256,000.
9600 is the default.
This parameter must be set to match your host computer.

Baud rate is the number of bits, including control bits (start/stop and
parity bits) transferred per second over the interface.

Data Bits

Values: 5 to 8 (default).
This parameter must be set to match your host computer.

Serial interfaces support 5, 6, 7, and 8-bit transfer of data words.
Most use 8-bit data transfer, but this must match the host computer.

Online State

Buffer State

Response Characters

Online

Buffer Empty

1 CR

Buffer Full

3 CR

Offline

Buffer Empty

0 CR

Buffer Full

2 CR