Siemens 2060isdn User Manual
Page 68
Operation with supplementary devices
68
I_KAP04.FM5
Gigaset 2060isdn, Inland:
8.12.98
A30853-X210-B101-1-19
Setting the device type
“Telephone” is the default device type for corded supple-
mentary devices. You should connect a modem or fax ma-
chine to socket 0 by preference, and if you connect a door
intercom you must use socket 9.
Set corded user lines (a/b lines):
t
Meaning: see footnote
Connecting telephones
You can connect a telephone to either of these lines and begin using it right away - no settings
are necessary. It is not necessary to register the telephone or other corded device at the base
station.
Deactivate “automatic line seizure” (➔ page 26) if you have a corded telephone connected to
the base station.
The dialing method (pulse or tone dialing) is recognized automatically. It is not possible to set up
two connections simultaneously using two corded devices.
The Signal key of a telephone connected to Gigaset 2060isdn has no function (exception: DTMF
telephones).
Call charges are not displayed on the telephone. The call charges incurred, however, are regis-
tered by the system. The call-charge totals per user and multiple subscriber number can be
viewed and deleted with the aid of a mobile unit registered at the base station.
Connecting corded devices (other than telephones)
You can use a mobile unit registered at the base station to enter the requisite settings for the
supplementary device. Activate “automatic line seizure” (➔ page 26) if you have a fax and/or
modem connected to the base station.
You can define the device you connect to the base station as a fax machine, modem, videotex
decoder, door intercom or answering machine (➔ page 68).
You can also set other user-specific parameters such as access rights, ring allocation and so on
for each supplementary device with the aid of a mobile unit.
A fax machine connected to a Gigaset 2060isdn must be configured for operation with a private
branch exchange (see the User Guide for your fax machine).
The maximum data-transfer rates you can use with the a/b lines are as follows:
●
Socket B (top), internal number 0: max. 28 800 baud
Ž
The comfort mobile unit is idle. You will be prompted to
enter the system code in the course of this procedure
(default code: “0000”).
.t Service
t System settings t Device data
t a/b line
t a/b line 0
Select a supplementary-device line. The alternatives are
a/b line 0 and a/b line 9.
u
x
Select a device type from the “Device type” menu and
save your choice. The current setting is marked “active”.
NEXT
SAVE
t means: browse withu
or
u
and
press x
to confirm
Z
NEXT
OK