beautypg.com

Operation with other mobile units – Siemens 2060isdn User Manual

Page 66

background image

Operation with other mobile units

66

I_KAP03A.FM5

Gigaset 2060isdn, Inland:

8.12.98

A30853-X210-B101-1-19

System settings

Operation with door intercom (int. No. 9)

Multicell operation

Set device type

Cordless user (1-8)

B # 1 SC*

)

O* 0 O (int. No.)

(1,2,3,4,6,7)**

Corded user (0)

B # 1

SC

*

)

O * 0 O (int. No.)

(0,2,3,4,6,7)

**

)

Corded user (9)

B # 1

SC

*

)

O* 0 O (int. No.)

(0,2,3,4,5,6,7)

**

)

Set internal collective call

B # 1

SC

*

)

O * 5 1 / 0 B

Activate/deactivate dialing of * / #

B # 1

SC

*

)

O # 5 1 / 0 B

Activate/deactivate trunk hold

(2-channel three-party conference, point-to-

multipoint)

B # 1

SC

*

)

O # 7 1 / 0 B

Activate/deactivate call transfer behind PBX

B # 1

SC

*

)

O # 8 1 / 0 B

Activate/deactivate permanent DTMF during

connect

B # 1

SC

*

)

O # 9 1 / 0 B

Unregister mobile unit

B # 7 2

SC

*

)

B

*

)

SC = system code of the base station (default code: “0000”)

**

)

0 no function, 1 mobile unit, 2 telephone, 3 modem, 4 fax, 5 intercom, 6 neutral, 7 answering machine

Set ring allocation

B # 1 SC*

)

O # 6 B

Answer call and operate door opener

Ring from door

c converse with party at door...

I

9 (door opener for 3 seconds.)

Answer call-waiting signal from door

Call...

B R

*

)

SC = system code of the base station (default code: “0000”)

Set multicell operation (all base stations)
(with basic access/behind PBX)

B # 1 SC*

)

O # * 0

0 / 1 B

Permit handover

B 1 B

Automatic handover

B

I

0 B

Display base-station number

B 3 6 1 B

Roaming when idle

automatic

Roaming when call in progress

Ext. call base station 1...

# ext. call base station 2...

*

)