beautypg.com

1q vlan current table information, 1q vlan current table information -57 – SMC Networks TigerStack 100 1000BASE-X User Manual

Page 75

background image

C

ONFIGURING

THE

S

WITCH

2-57

802.1Q VLAN Current Table Information
This screen shows the current port members of each VLAN and whether
or not the port supports VLAN tagging. Ports assigned to a large VLAN
group that crosses several switches should use VLAN tagging. However, if
you just want to create a small port-based VLAN for one or two switches,
you can assign ports to the same untagged VLAN. The current
configuration is shown in the following screen.

MAX Supported VLANs Maximum number of VLANs that can be configured

on this switch.

Current Number of

VLANs Configured

The number of VLANs currently configured on this

switch.

Parameter

Description

Deleted VLAN Entry

Counts

The number of times a VLAN entry has been deleted

from this table.

VID

The ID for the VLAN currently displayed.

Parameter

Description

802.1Q VLAN Current Table Information
=====================================

Deleted VLAN Entry Counts : 0

VID

Creation Time

Status

--------------------------------------------------

1

0 (0 day 0 hr 0 min 0 sec)

Permanent

Unit

Current Egress Ports

Current Untagged Ports

1. 111111111111 111111111111 ----

111111111111 111111111111 ----

2. ------------ ------------ ----

------------ ------------ ----

3. ------------ ------------ ----

------------ ------------ ----

4. ------------ ------------ ----

------------ ------------ ----

5. ------------ ------------ ----

------------ ------------ ----

6. ------------ ------------ ----

------------ ------------ ----

Sorted by VID : 1

[Show]

[More]

Use or arrow keys to move. to select.

Port 1 Port 13 Port 25