Appendix

The command is sent from PC to the projector with the
format below;

'CR' [Command] 'CR'

Command: one character (refer to the command table
below.

The projector decodes the command and returns the
'Character string' with the format below;

Format

The tables on page 89 and 90 show the typical command lists for controlling the projector. Please consult your local dealer
for further information of other commands.

Command

Function

Projector

Return

Projector status

CR0

Status Read

00

Power On

80

Stand-by mode

40

Countdown

20

Cooling down

10

Power Malfunction

28

Cooling down at the temperature anomaly

24

Cooling down at Power Management mode

04

Power Management mode after Cooling down

21

Cooling down after the projector is turned off when the lamps
are out.

81

Stand-by mode after Cooling down when the lamps are out.

88

Stand-by mode after Cooling down at the temperature
anomaly.

CR6

Temperature Read

S1 S2 S3

S1 = Temperature at Sensor 1 (˚C)
S2 = Temperature at Sensor 2 (˚C)
S3 = Temperature at Sensor 3 (˚C)
(ex.) S1 = 12.3˚C��� S2 = 23.4˚C��� S3 = 34.5˚C

��� S2 = 23.4˚C��� S3 = 34.5˚C

S2 = 23.4˚C��� S3 = 34.5˚C

--> The projector displays “12.3 23.4 34.5”
( For each sensor, two digit and the tenth place numbers are

displayed with a space between each temperature.)

?

Communication failure

Status Read Command