5. Details of simulations
Simulation input procedure: C
→
л
→
0
→
л
Main code
Sub code
Content
01
01
Mirror operation check
When the print button is pressed, the mirror is scanned at a speed corresponding to the currently set copy
magnification ratio.
The copy magnification ratio can be arbitrarily set.
02
Optical system sensors (MHPS, LHPS) state display
ON/OFF state of the optical system sensor can be monitored by the LED on the operation panel.
Sensor name
Operation panel LED
MHPS
Paper empty lamp (
ç
)
LHPS
JAM lamp (
ê
)
03
Lens operation check
The lens unit moves to the following positions of the magnification ratios continuously.
AB series: 100%
→
115%
→
122%
→
141%
→
200%
→
86%
→
81%
→
70%
→
50%
→
100%
Inch series: 100%
→
121%
→
129%
→
141%
→
200%
→
95%
→
77%
→
64%
→
50%
→
100%
04
Lens aging
The operation of SIM 1-3 is repeated continuously.
02
01
ADF aging
The ADF original transport operation is performed.
02
ADF sensors states display
The ADF sensors ON/OFF states can be monitored with the LED on the operation panel.
When the third digit of the multi display is “A,” the following display is made.
Sensor name
Operation panel LED
Original set sensor
JAM lamp (
ê
)
Resist sensor
Paper empty sensor (
ç
)
Timing sensor
Drum position jam lamp (
▼
)
Repulsion sensor
Resist position jam lamp (
▼
)
ADF open/close sensor
ADF position jam lamp (
▼
)
Paper feed cover sensor
Paper exit position jam lamp (
▼
)
Reversing section cover sensor
Manual paper feed selection lamp
If, at that time, the magnification ratio display key is pressed, the third digit of the multi display is changed to “B”
and the following display is made.
Sensor name
Operation panel LED
Tray width sensor (297mm, 11")
First step cassette lamp
Tray width sensor (257mm)
Second step cassette lamp
Tray width sensor (210mm, 8.5")
Third step cassette lamp
Tray width sensor (182mm)
Fourth step cassette lamp
Tray vertical sensor (240mm)
Resist position jam lamp (
▼
)
Tray vertical sensor (300mm)
Paper exit position jam lamp (
▼
)
Original width size sensor
Manual feed selection lamp
03
ADF individual load operation check (paper feed motor forward rotation)
04
ADF individual load operation check (paper feed motor reverse rotation)
05
ADF individual load operation check (transport motor forward rotation)
06
ADF individual load operation check (transport motor reverse rotation)
07
ADF individual load operation check (Repulsion motor forward rotation) A57 only
08
ADF individual load operation check (Paper feed solenoid)
09
ADF individual load operation check (Reverse rotation solenoid) A57 only