Sharp SF-1120 User Manual
Page 85
Make an original for adjustment.
Draw parallel lines at 10cm from the both edges of an A3 or
11"
×
17" white paper. (Be careful to draw precisely parallel
lines.)
(2)
Set the adjustment original made in (1) as shown below.
(3)
Make a normal (100%) copy on an A3 or 11"
×
17" white
paper.
(4)
Measure the distances at four points as shown below:
Adjustment procedure (1)
When La>Lb (Lc frame side of the No. 4/5 mirror base unit. When La frame side of the No. 4/5 mirror base unit. is rotated from the original position. When the eccentric If the above adjustment is not effective, then follow Adjustment procedure (2) 1 Move the mirror base rail B up and down in the arrow directions • When La > Lb, shift the mirror base B rail upward by half of • When La < Lb, shift the mirror base B rail downward by half of 10mm 10mm 10mm 10mm Parallel line Parallel line Blank paper Fit the original edge with the Glass holding plate Adjustment original La Lb Ld Lc Paper No. 4/5 mirror base Hole for screwdriver Mirror base rail handle Loosen Loosen 1 scale = 1mm 7 – 11Ld): Rotate to decrease the height of the front
Open the front cabinet, insert a screwdriver
as shown below, and turn the eccentric
screw to adjust the height of the No. 4/5
mirror base.
screw is turned 36 degrees, the height of the front frame
side of the No. 4/5 mirror base is increased or decreased
by 2mm and the difference (La – Lb) is varied by 4mm.
the Adjustment procedure (2) .
to adjust.
the difference of La – Lb.
the difference of La – Lb.
glass holding plate edge
discharge
direction