[10] SERVICING AT MEMORY TROUBLE AND MAIN CONTROL PWB RE-

PLACEMENT

1. General

The EEPROM in the control PWB and the EEPROM are storing
various set values, adjustment values, and counter values.
These data are very important and used for operating the machine
properly and for service control.
In the following cases, therefore, various set values, adjustment
values and counter values must be set again.

*

When memory trouble (U2) occurs.

*

When the EEPROM in the main control PWB is replaced.

*

When the main control PWB is replaced.

When "U2" trouble occurs, the data cannot be relied upon, and they
must be set properly.

2. Purpose

The purpose is to reset the memory data to operate the machine
properly.
Use the attached service memory data recording sheet to memorize
the newest data when servicing in order to cope with the above
situations. This improves efficiency in servicing and realizes quick
recovery.

3. Remedies

Perform the procedures according to the following flowcharts.
"Sim" in the flowchart means "Simulation."

Memory trouble

Procedures for memory trouble, main control PWB replacement,
and main control PWB EEPROM replacement

NO

YES

"U2" trouble

occurs

Do you replace

the main control

PWB?

Replace the main

control PWB

Cancel "U2" trouble

with simulation 16

1

Repair the

defective section

NO

YES

Is the

EEPROM in

the main control
PWB defective?

Replace the main

control PWB

Mount the EEPROM of

the old main control to

the new main control

Replace the main

control PWB

End

Replace the

EEPROM in the

main control PWB

1

Replace the EEPROM

10 – 1