Set value recording sheet – Sharp SF-1120 User Manual
Page 117
4. Set value recording sheet
Memorize set values in the column of "Set value" for efficient servicing when the memory trouble occurs and the EEPROm is replaced.
Make a copy of this sheet and use with the service sheet.
Purpose/kind
Section
Contents
Main code
Sub code
Set value
Description
Adjustment
Paper feed section
51
02
Adjustment value of contact pressure of the paper on the main
body resist roller
Optical unit
50
01
Copy paper lead edge void amount adjustment
(Resist adjustment A)
Copy paper lead edge void amount adjustment
(Resist adjustment B)
Copy paper lead edge void amount adjustment
(Lead edge void adjustment )
Copy paper lead edge void amount adjustment
(Rear edge void adjustment)
46
01
Adjustment value of copy density (exposure level) in each copy
mode and of copy density gradient (exposure gradient)
Manual copy mode density level 1
Manual copy mode density level 5
Manual copy mode density level 1 (Toner save mode)
Manual copy mode density level 5 (Toner save mode)
Auto copy mode density level 1 (Not toner save mode)
Auto copy mode density level 5 (Not toner save mode)
Auto copy mode density level 1 (Toner save mode)
Auto copy mode density level 5 (Toner save mode)
Photo copy mode density level 1 (Not toner save mode)
Photo copy mode density level 5 (Not toner save mode)
47
The AE sensor and the optical section characteristics memory
data for the change in the copy lamp application voltage
48
01
The vertical copy magnification ratio adjustment value
02
The horizontal copy magnification ratio adjustment value (when
the document table is used)
Developing unit
25
02
Toner density initial set value
Setting
Specifications
26
06
Destination specifications
Fuser unit
26
13
Setting of the main motor operation mode in warming up
43
01
The set value of fusing temperature
Maintenance counter
21
01
Setting of the maintenance cycle
Counter
Developing unit
22
06
The developer count of the installed developer unit can be
checked.
07
The developer replacement cycle of the installed developer unit
can be checked.
10 – 3