beautypg.com

Sharp SF-1120 User Manual

Page 66

background image

6-3. Drum (Replace every 50K copies)

1

Remove the process unit from the copier. (Refer to 6-1.)

2

Loosen two blue screws which are fixing the drum, rotate the plate
slightly to the right and pull it out.

3

Remove the drum.

Be careful not to scratch the drum.

6-4. Blank lamp unit (Clean every 50K copies.)

1

Remove three blue screws which are fixing the process unit
holder, slide the holder and remove it.

2

Tighten the blank lamp unit position adjustment screw completely,
and remove the unit rear side, then loosen the screw.

3

Remove two connectors of the blank lamp PWB, and remove the
blank lamp unit.

When the unit is installed or replaced, adjust according to

"Blank lamp position adjustment" in [7] ADJUSTMENTS.

6-5. Discharge lamp unit (Clean every 50K copies.)

1

Remove three blue screws which are fixing the process unit
holder, slide the holder and remove it.

2

Remove the discharge lamp unit. (one screw, one connector)

6 – 19