5. Memory simulation list

Purpose/kind

Section

Contents

Ref. page

Main
code

Sub

code

Default

value

Description

Adjustment

Paper feed
section

51

02

50

Adjustment value of contact pressure of the paper on the main
body resist roller

8-19

Optical unit

50

01

Copy paper lead edge void amount adjustment
(Resist adjustment A)

8-18

Copy paper lead edge void amount adjustment
(Resist adjustment B)

Copy paper lead edge void amount adjustment
(Lead edge void adjustment )

Copy paper lead edge void amount adjustment
(Rear edge void adjustment)

46

01

Adjustment value of copy density (exposure level) in each copy
mode and of copy density gradient (exposure gradient)

8-17

Manual copy mode density level 1 (Not toner save mode)

Manual copy mode density level 5 (Not toner save mode)

Manual copy mode density level 1 (Toner save mode)

Manual copy mode density level 5 (Toner save mode)

Auto copy mode density level 1 (Not toner save mode)

Auto copy mode density level 5 (Not toner save mode)

Auto copy mode density level 1 (Toner save mode)

Auto copy mode density level 5 (Toner save mode)

Photo copy mode density level 1 (Not toner save mode)

Photo copy mode density level 5 (Not toner save mode)

47

The AE sensor and the optical section characteristics memory data
for the change in the copy lamp application voltage

8-17

48

01

50

The vertical copy magnification ratio adjustment value

8-17

02

50

The horizontal copy magnification ratio adjustment value (when the
document table is used)

8-18

Developer unit

25

02

Toner density initial set value

8-9

Setting

Specifications

26

06

Specifications setting by destination

8-10

Fuser unit

26

13

0

Setting of the main motor operation mode in warming up.

8-10

43

01

185°C

Fusing temperature set value

8-13

Maintenance
counter

21

01

Maintenance cycle setting

8-8

02

Mini maintenance cycle setting

8-8

Developer unit

22

06

Used to confirm the developer counter value of the installed
developer unit.

8-8

07

Used to confirm the developer replacement cycle of the installed
developer unit.

8-8

Code No.

Destination

0

Japan

1

U.S.A.

2

Canada

3

Europe except U.K.

4

U.K.

5

Australia

6

Inch series outside Japan

7

AB series outside Japan

Code

No.

Operation

mode

Operation

0

Normal

mode

When the fusing temperature reaches
the specified level, the main motor stops.

1

Long

mode

The main motor keeps rotating until the
completion of the warming up.

10 – 4