beautypg.com

Sharp SF-1120 User Manual

Page 71

background image

9-4. Main PWB unit

1

Remove the rear cabinet upper.

2

Disconnect all the connectors (6 connectors) connected to the
main PWB.

3

Remove the main PWB plate (one screw).

4

Remove the main PWB from the plate. (2 screws)

9-5. AC power PWB

1

Remove the main PWB unit. (Refer to 9-3.)

2

Remove the rear cabinet lower.

3

Remove all the connectors (11 connectors) of the AC power PWB
and remove one grounding wire connected between the AC power
PWB and the copier chassis.

4

Remove two screws which are fixing the AC power PWB, and
remove the PWB.

9-6. Ozone filter (Check every 50K copies, and

clean every 100K copies.)

1

Remove the upper cabinet left, and the left cabinet. (5 screws)

2

Remove the ventilation fan motor (2 screws). (SF-2020)

3

Remove the process unit. Insert a screwdriver from the process
unit position into the copier to push out the oZone filter. (SF-2020)

(SF-2120)

(SF-2020)

6 – 24

This manual is related to the following products: