beautypg.com

Sharp SF-1120 User Manual

Page 102

background image

Main code

Sub code

Content

41

01

Original sensor check

Used to display the judgement result of the original sensor on the operation panel LED.

The original sensor values are read sequentially. If the sensor is interrupted (judged as presence of an original),
the LED corresponding to the sensor position is turned on.

Sensor name

Operation panel LED

PD0

Original size LED A5/INV

PD1

Original size B5

PD2

Original size A4/LT

PD3

Original size B5R

PD4

Original size A4R/LTR

PD5

Original size B4/LG

PD6

Original size A3/WLT

OCSW

Manual feed tray selection LED

When the original cover is closed, the original sensor is not read and it is judged as no original at all. (All the
original size LED’s are turned off.)

Since the machines for Japan/Taiwan are not equipped with the PD0 sensor, the original size LED display is not
made.

For the other areas, PD1 and PD3 sensors are not provided and the original size LED display is not made.

02

Original sensor adjustment

The original sensor input values of original presence and original empty are read to set the original judgement
level.
When this simulation is executed, “1” is displayed on the copy quantity display and the ready lamp lights up.
First, in order to read the original sensor input value of original empty, press the PRINT button without an original
on the original table with the original cover open. The copy quantity display will change to “2.”

Then, in order to read the original sensor input value of original presence, press the PRINT button with an A3
paper on the original table. The copy quantity display will change to “0.” Then the operation of SIM 41-1 is
performed.

After completion of reading the original sensor inputs, the average value of the two inputs is stored as the original
judgement level.

03

Original sensor light reception level and original judgement level display

Used to display the original sensor light reception level and the original judgement level on the copy quantity
display.

Display is selected by the magnification ration selection key.

Since there are two or more display items, the third digit is used to make distinction between the light reception
level and the original judgment level, and the lower two digits are used to display the data. The currently set
original sensor is displayed by the LED on the original size display section. The relationship between the sensor
name and the original size LED is the same as SIM 41-1.

Copy quantity display

Original size

display

Display data

3rd digit

2nd, 1st digits

A

Current light
reception level

A5/INV

PD0 current light reception level

B5

PD1 current light reception level

A4/LT

PD2 current light reception level

B5R

PD3 current light reception level

A4R/LTR

PD4 current light reception level

B4/LG

PD5 current light reception level

A3/WLT

PD6 current light reception level

b

Original
judgement level

A5/INV

PD0 original judgement level

B5

PD1 original judgement level

A4/LT

PD2 original judgement level

B5R

PD3 original judgement level

A4R/LTR

PD4 original judgement level

B4/LG

PD5 original judgement level

A3/WLT

PD6 original judgement level

OCSW

Manual feed tray selection LED

The data displayed by the lower two digits are A/D input values of the original sensor, and is expressed in
hexadecimal. (Display range: 0

FFh)

The light reception level display is changed only when the original cover is open.

PD1 PD2 PD3 PD4

PD5 PD6

D

ocum

ent

lead

eddge

8 – 12

This manual is related to the following products: