beautypg.com

Sharp SF-1120 User Manual

Page 59

background image

5

Remove the drive springs 4 and 5.

6

Remove the zooming rack of the roll holder unit.

7

Remove the lens drive shaft attachment plate.

8

Remove the drive shafts 4 and 5.

*

When removing the No. 4/5 mirror unit, remember the positions
(scales) of the arrow marks of the drive holder 4 and 5.

B. No. 4/5 mirror unit assembly

Reverse the above procedures.


When attaching the lens drive shaft attachment plate, attach it to
position 5 in the above description.
Fit the arrow positions of the drive holder 4 and 5 as the previous
state.

*

When the arrow positions cannot be fit:

1

Loosen the zooming rack screw and slide it to adjust.

2

Loosen the two screws which are fixing the driver holder 4 and 5
and the drive latch 4 and 5. Adjust with the drive holder 4 and 5.
After completion of adjustment, tighten the two screws.

Zooming rack

No.4/5
adjustment
screw

No.4/5 drive latch
stop screw

No.4/5 drive holder

Zooming rack

No.4/5
adjustment
screw

No.4/5 drive latch
stop screw

No.4/5 drive holder

6 – 12