6-6. Cleaner blade (Replace every 50K copies.)

1

Remove the holder from the process unit. (3 blue screws)

2

Remove the cleaning blade. (3 blue screws)

6-7. Drum separation pawl (Replace every 50K

copies.)

Slide and remove the blue pin to remove the separation pawl.
Replace the star-shape washer with a new one if it is worn down.

6-8. Process control PWB (Clean the sensor

section every 50K copies.)

1

Remove the holder from the process unit (3 blue screws), and
remove the connector of the process control PWB.

2

Remove the holder of the process control PWB (2 screws), and
remove the PWB (2 screws).

6-9. Drum mark sensor PWB (Clean the sensor

section every 50K copies.)

Remove the holder from the process unit (3 blue screws), and
remove the marking sensor PWB. (1 screw).

6-10. Toner reception seal (Replace every 50K

copies.)

Remove the drum and remove two screws to remove the seal.

7. Developing section

A. DV side seals F/R replacement (Replace every 120K

copies.)

1

Remove two screws which are connecting the hopper section and
the developing unit, and separate them each other.

2

Replace the developing unit side seals F/R as shown below.

Note: Since the developing side seals are in the vicinity of the drum,

be careful of peeling off and defective attachment.

Fixing screw

Toner hopper

Fixing screw

Developing unit

(Side seal R attachment reference)

(Side seal F attachment reference)