2-3. Adjustment of each section

A. Lens reference position adjustment

In this model, the reference value according to each lens charac-
teristics must be entered. With this value, the lens home position is
determined.


(1)

Execute simulation 48-01

Perform the following key operation.

"A" is displayed on the third digit of the copy quantity dis-
play, and the previously set value or 50 is displayed on the
second and the first digits.

Substitute the "O – L" value (variation in the distance be-
tween the original and the lens) on the lens value label at-
tached to position B shown in the figure below into the follow-
ing formula, and input the obtained value.

50 – {(O – L value)

×

5} = Correction reference value

When the lens value is +1.2;

50 – (1.2

×

5) = 44 (Correction reference value = input

value)


Be sure to check that the magnification ratio cam is at the home
position as shown in the figure below.

B. No. 4/5 mirror reference position adjustment


(1)

Remove the external fittings.

(2)

Loosen two screws (A) which are fixing the No. 4/5 mirror and
the No. 4/5 mirror drive holder to the No. 4/5 mirror holder.

ë

C

0/

4

PSW

1

PSW

8

ë

1

2

3

4

5

6

7

8

9

0/

C

Numerals

B (Lens value label)

Lens

51 50 49

Screw A

No.4/5
drive rack

No.4/5 drive holder

No.4/5 mirror holder

7 – 4