Trouble code
Sub code
Content
Condition
F1
00
Sorter communication error
•
An error occurred in communication between the sorter and
the main unit.
02
Transport motor trouble
•
During rotation of the transport motor, the rotation pulse is
not sensed for 0.5 sec or more.
04
Bin upper limit/lower limit trouble
•
When shifting the bins, the upper limit or the lower limit is
erroneously sensed.
05
Bin home sensor trouble
•
When initializing the bins, the bin home sensor is not
sensed within 1 sec.
06
Bin motor trouble
•
During rotation of the bin motor, the rotation pulse is not
sensed for 0.5 sec or more.
14
Take-out sensor trouble
•
When the take-out sensor A/D input value is 3V or more.
16
Grasping motor trouble
•
During rotation of the grasping motor, the rotation pulse is
not sensed for 0.05 sec.
F2
31
Image density sensor trouble
•
When the light emitting quantity of the image density
sensor is increased to the maximum level, the input value
does not reach 3.75V.
•
When the light emitting quantity of the image density
sensor is decreased to the minimum level, the input value
does not fall below 4.5V.
•
During execution of the grid voltage correction, the element
level is 3V or lower.
32
Drum mark sensor trouble
•
During one and a quarter rotations of the drum, the drum
mark is not sensed (the sensor input does not become
HIGH).
•
The drum mark sensor input level is not in the specified
range.
33
Grid voltage correction trouble (Limit
over)
•
When obtaining the grid voltage correction value, the result
of the patch voltage is not in the range of 200
∼
650V.
35
Grid voltage correction trouble
•
When obtaining the grid voltage correction value, the patch
voltage is not in the range of 200
∼
650V.
•
The grid voltage correction cannot be performed properly.
(The correction value cannot be obtained.)
37
Drum mark sensor gain adjustment
trouble
•
Though the drum mark sensor light emitting quantity is
increased to 1.45V, the sensor input level does not become
LOW.
EE
EU
Auto developer adjustment under
toner detection
•
After completion of the auto developer adjustment
(simulation 25-2), the toner density sensor input voltage is
over the specified range. (Under toner)
EL
Auto developer adjustment over
toner detection
•
After completion of the auto developer adjustment
(simulation 25-2), the toner density sensor input voltage is
under the specified range. (Over toner)
CC
Original detection trouble
•
When the original detection sensor judgement level setting
(SIM 41-2) is performed, the difference between the original
presence level and the original empty level is too small.
9 – 3