beautypg.com

Sharp SF-1120 User Manual

Page 86

background image

(Example) When La=12mm and Lb=9mm, shift the paper exit side

mirror base B rail upward by 1.5mm.

When Lc > Ld, shift the mirror base B rail downward by half of
the difference of Lc – Ld.

When Lc < Ld, shift the mirror base B rail upward by half of
the difference of Lc – Ld.

(When moving the mirror base rail, hold the mirror base rail handle.)

2

Adjust according to procedure (1) so that La=Lb and Lc=Ld are
satisfied.

3

After completion of the adjustment, turn the mirror base drive
pulley manually to full scan mirror base A and mirror base B,
and check that the mirror bases are not brought into contact
with each other.

(Note) When the mirror bases are moved extremely, they

may be brought into contact. Carefully avoid it.

I. Center shift adjustment

a. This adjustment must be performed in the following cases:

The copy (100%) center is shifted from the original center
more than 2mm.

When any part of the lens rail or the lens unit is replaced.


(1)

make a test chart for center position adjustment. (Refer to the
figure below.)

(2)

Set the test chart for the center position adjustment to the
document reference line, and make a normal (100%) copy with
an A4 or 11"

×

8

1

2

" paper.

(3)

Check that the copied image line is at the center of the copy
paper.

(4)

If the error of the copy image line is within the specified range
(0

±

2.0mm), the adjustment is not required. If not, perform the

following procedures.

(5)

Remove the document reference plate and the right upper side
cabinet, and remove the document table glass.

(6)

Loosen the three fixing screws of the optical system unit and
slide the optical system unit to adjust the center position.

(7)

After adjustment, set the removed parts in the reversed se-
quence. make a copy of the test chart to check that the center
shift is within the specified range (0

±

2.0mm). If the center shift

is within the specified range, the adjustment is completed. If
not, repeat procedures (2) – (7) until it is within the specified
range.

J. Exposure balance adjustment

a. This adjustment is to provide uniform exposure, and must be

performed in the following cases:

When the reflector is replaced.

When the copy lamp is replaced.

When the exposure adjustment plate is replaced.


(1)

Set a half tone paper on the original table and make a half
tone copy at 100%.

(2)

If the exposure of the half tone copy is uniform, the adjustment
is not required. If it is varied as shown below, perform the
following procedures.

Draw a line at the center

Copy paper
(A4 or 11" x 8½")

Paper transport direction

(Copy A)

(Copy B)

2.0mm or less

Shift

2.0mm or less

Shift

Copy image

Copy paper
fold

Copy paper
fold

Copy image

(Paper feed direction)

Document
reference plate

Document table glass

Right upper side cabinet

A

B

Original
center

(Original)

Copy
paper
center

Copy
paper
center

(Copy 1)
Move lens is the A direction

(Copy 2)
Move lens is the B direction

2mm
or less

2mm
or less

Optical system
unit

Loosen the
screws
(3pcs.)

Lens bearing side

Lens
body
side

Paper
discharge
direction

Half-tone copy

Exposure
insufficient

7 – 12