beautypg.com

24 volt gasoline, diesel, or propane forklifts, Electric forklifts up to 60 volts, 24 volt gasoline, diesel, or propane forklifts -9 – Symbol Technologies VC5090 User Manual

Page 33: Electric forklifts up to 60 volts -9, Installation 2 - 9

background image

Installation

2 - 9

12-24 Volt Gasoline, Diesel, or Propane Forklifts

All power wiring must use the supplied power cable.

Fuses:

two 3AG, 20A, 250V, SLO BLO fuses

one 3AG, 1A, 250V, SLO BLO fuse.

Keep the path between the battery and the vehicle computer as short as possible, and away from any

part of the ignition high tension system.

Figure 2-9

Wiring Diagram

Electric Forklifts Up to 60 Volts

All power wiring must use the supplied power cable.

Fuses:

two 3AG, 20A, 250V, SLO BLO fuses

one 3AG, 1A, 250V, SLO BLO fuse.

NOTE

The vehicle computer contains an Ignition Sense feature that detects when the ignition switch is turned

off and shuts the vehicle computer down after a preprogrammed timeout. This feature allows the operator

to use the vehicle computer for a predetermined time period after the ignition switch is turned off, then

shuts the vehicle computer down automatically to prevent over-discharge of the forklift battery. The

timeout period is adjustable by the user (see Ignition Sensing on page 3-17 for setting the timeout value).

The normal current draw of a suspended vehicle computer is approximately 500mA. When the vehicle

computer shuts down using the Ignition Sense feature, current draw is reduced to approximately 5 mA.

This feature provides the automatic shutoff functionality of an external relay, without requiring an actual

relay and has the added benefit of allowing the user to work for a preset time period before shutting

down.

VC5090

20A Fuse

1A Fuse

Ignition

Switch

20A Fuse

Chassis Ground

Vehicle

Battery

Power Cable

25-71919-01

Yellow

Red

Green

Black