background image

Application Development and Deployment 7 - 13

8.

IPL displays the

Select Transport

menu which lists the available methods of downloading the file.

Figure 7-10

Select Transport Menu

9.

Scroll to select

USB

or

Lighthouse 0 - Serial

transport, then press

P2

.

10.

If you selected the

Lighthouse 0 - Serial

transport method:

a.

the

Baud Rate Menu

appears.

Figure 7-11

Baud Rate Menu

Power Micro

The Power Micro is a small computer contained within the vehicle computer that controls

several system resources. In the unlikely event that the Power Micro Firmware needs

updating, selecting this item allows the device to be programmed.

Partition Table

Contains the partition information for all other partitions.
Note: The partition table should never need changing unless the sizes of the platform and

application images are changed within TCM. If this is done, then the new partition table

should be loaded first, followed by both platform and application in any order.

Command File

Select to load a command file. A command file is a file that allows you to automatically load

a number of partitions in a batch process.

System Reset

Selecting this item provides a simple method to exit IPL and to boot the operating system.

Auto Select

Selecting this item allows one or more files to be downloaded without having to manually

select the destination. (The content of the files being downloaded automatically directs the

file to the correct destination.) For technical reasons, Auto Select cannot be used to

download Monitor, Power Micro, or Partition Table. These items must be specifically

selected.

Select Transport

USB

SD/MMC

Lighthouse 0 - Serial

Previous

Top

Table 7-2

IPL Menu Partitions (Continued)

Partition Name

Description

NOTE

You must disable USB ActiveSync on the development computer.

Baud Rate Menu

115200

57600

38400

19200

9600

Previous

Top