PTP Configuration

96154 • Revision K

Chapter 2 Configuration Information 33

Perform audits in a specific sequence to avoid loss or mismatch of VOLIDs. first audit

the library with the highest numbered LSMs. The audit process must proceed sequentially

from left-to-right, as shown in

TABLE 2-4

. Audit the newly added library (lowest

numbered LSM) last.

FIGURE 2-1

shows how the libraries are configured when adding a PTP to an exiting

library complex.

TABLE 2-4

Adding a Library to the Right

Exiting Libraries

New Library

First Audit
Library A

Second Audit
Library B

Last Audit
Library C

Renumbers LSMs 4-7 to 8-11 Renumbers LSMs 0-3 to 4-7

Assigns LSM numbers 0-3

FIGURE 2-1

Adding a PTP to an Existing Library Complex

An existing Library complex has two libraries (A and B), connected with a PTP.
A = The home library contains LSMs 0—3.
B = The away library contains LSMs 4—7

In this example, adding another library (C) to the left
of the library complex increases the LSM numbering
sequentially. This is the preferred method.

In this example, adding another library (C) to the
right of the library complex requires a
reconfiguration of LSM numbering.

New library C added to the

of libraries A and B with

a Pass-thru Port

left

C

LSM 8

9

10

11

Front

Pass-thru Port connecting
existing libraries A and B

L203 875

New library C added to the

of libraries A and B with

a Pass-thru Port

right

B

LSM 8

9

10

11

Front

Existing libraries A and B
connected with a
Pass-thru Port

L203 876