beautypg.com

Table 6-1 – Sun Microsystems StreamLine SL8500 User Manual

Page 140

background image

Troubleshooting the Library

100 StreamLine™ SL8500 Modular Library System User's Guide • March 2007

Revision K • 96154

TABLE 6-1

Troubleshooting Table

Problem

What to do

Service Required (red)
LED is constantly lit.

Perform the following procedure:
Use the StreamLine Library Console to check the health of the library and the
attached devices (drives, CAP, robots, and elevators).
To perform a health check:
1. Launch the Library Console application.
2. Access the System Detail module (Tools > System Detail).
3. Check the device tree for the following indicators:
Device Healthy

Device Error

Note –

The device tree is on the left panel that

provides a list of devices attached to the library (drives,

CAP, robots, elevator).

The Status (for example, online/offline) tab provides more information on the
health of the library and devices. For more information, see the online help
documentation accessible through the Library Console application.
Other checks:
• Make sure that all cartridges are fully seated and properly oriented in their

slots.

• Inspect the library floor for any foreign objects or debris; remove any objects

you find.

CAP unlocked LED is lit
and blinking.

Open the CAP and make sure the cartridges in the CAP slots are properly
seated. See

“To open the CAP” on page 47

.

The client computer
cannot communicate with
the library or drives.

Make sure that all cables are securely attached to their connectors on the rear of
the library, the drives, and the client computer.