beautypg.com

Severity codes, Severity codes 137, Table c-2 – Sun Microsystems StreamLine SL8500 User Manual

Page 177

background image

SNMP Traps/Notifications

96154 • Revision K

Appendix C SNMP 137

Activity string (such as “HLI move” or “CLI version print”)

A descriptive text string

Other information may include:

Date and time

Device address associated with the event

User name associated with the activity (such as “HLI host,” “advsrv”)

The interface-specific request identifier (such as “HLI000001”)

Severity Codes

SMNP Traps are grouped into three categories. These categories are listed in

TABLE C-2

. Other categories may be added in the future.

TABLE C-2

Trap Severity Codes

Group

Type

Summary

Description

1

Error

Errors critical to library
operation. Provide all
machine analysis
information.

Device inoperable: refers to the entire
system. Failure of a sub-unit or redundant
component is not a Category “1.”

2

Warning

Conditions that may require
attention.

Device degraded: refers to recoverable
failures that may allow the system to
remain in use, but only in a degraded
mode.

11

SNMP Agent Start Up

The SNMP Agent has started