17 field-orientated control, Limitations – Siemens MICROMASTER 440 User Manual
Page 50
6 Commissioning
Issue 10/06
MICROMASTER 440
50
Operating Instructions (Compact)
6.4.17 Field-orientated
control
Limitations
To avoid a premature limitation the limits of the torque (P1520, P1521) and power
(P1530, P1531) should be set to the maximum value, if the application allows it.
Motor overload factor [%]
Defines motor overload current limit in [%] relative to p0305 (rated motor current). Limited to
maximum inverter current or to 400 % of rated motor current (p0305), whichever is the
lower.
100
p0305
p0305)
4
(r0209,
min
p0640
max
⋅
⋅
=
CO: Upper torque limit
Specifies fixed value for upper
torque limitation.
P1520
max
P1520
def
r0333
1.5
⋅
=
r0333
4
⋅
±
=
CO: Lower torque limit
Enters fixed value of lower
torque limitation.
P1521
max
P1521
def
r0333
1.5
⋅
−
=
r0333
4
⋅
±
=
f
1
~
Torque limitation
Resultant
torque limit
Power
limitation
|f
act
r1526
r1527
Stall
limitation
p1530
p1531
f
1
~
2
Constant
torque
f
stall
Constant
power
|
|M|
Stall
power
Motoring power limitation
Defines fixed value for the max. permissible
motoring active power.
P1530
def
P1530
max
0307
P
3
⋅
=
0307
P
5
.
2
⋅
=
Regenerative power limitation
Enters fixed value for the max. permissible
regenerative active power
P1531
max
P0307
3
-
⋅
=
P1531
def
P0307
2.5
-
⋅
=
M
f
f
2
P
M
⋅
π
⋅
=
Power limitation (motoring, regenerative)
p1530
p1531
p1530
p1531
p0640 = ...
150.0 %
P1520 = ...
P1521 = ...
P1530 = ...
P1531 = ...
FC-spec.
FC-spec.
FC-spec.
FC-spec.