Siemens MICROMASTER 440 User Manual
Page 10
2 Electrical Installation
Issue 10/06
MICROMASTER 440
10
Operating Instructions (Compact)
Input voltage range
3 AC 380 V – 480 V. ± 10 %
(Unfiltered)
Order No.
6SE6440- 2UD13
-7AA1
2UD15
-5AA1
2UD17
-5AA1
2UD21
-1AA1
2UD21
-5AA1
2UD22
-2BA1
2UD23
-0BA1
2UD24
-0BA1
2UD25
-5CA1
2UD27
-5CA1
Frame Size
A B
C
[kW]
0,37 0,55 0,75 1,1
1,5 2,2 3,0 4,0 5,5 7,5
Output Rating(CT)
[hp]
0,5 0,75 1,0 1,5 2,0 3,0 4,0 5,0 7,5 10,0
Output Power
[kVA]
0,9 1,2 1,6 2,3 3,0 4,5 5,9 7,8 10,1 14,0
CT-Input Current 1)
[A]
2,2 2,8 3,7 4,9 5,9 7,5 10,0 12,8 15,6 22,0
CT-Output Current
[A]
1,3 1,7 2,2 3,1 4,1 5,9 7,7 10,2 13,2 19,0
VT-Input Current 1)
[A]
- - - - - - - -
17,3
23,1
VT-Output Current
[A]
- - - - - - - -
19,0
26,0
Fuse [A]
10 10 10 10 10 16 16 20 20 32
Recommended 3NA
3803 3803 3803 3803 3803 3805 3805 3807 3807 3812
For UL specified
*
*
*
*
*
*
*
*
*
*
[mm
2
]
1,0 1,0 1,0 1,0 1,0 1,5 1,5 2,5 2,5 4,0
Input Cable, min.
[AWG]
18 18 18 18 18 16 16 14 14 12
[mm
2
]
2,5 2,5 2,5 2,5 2,5 6,0 6,0 6,0 10,0 10,0
Input Cable, max.
[AWG]
14 14 14 14 14 10 10 10 8 8
[mm
2
]
1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 2,5 4,0
Output Cable, min.
[AWG]
18 18 18 18 18 18 18 18 14 12
[mm
2
]
2,5 2,5 2,5 2,5 2,5 6,0 6,0 6,0 10,0 10,0
Output Cable, max.
[AWG]
14 14 14 14 14 10 10 10 8 8
[kg]
1,3 1,3 1,3 1,3 1,3 3,3 3,3 3,3 5,5 5,5
Weight
[lbs]
2,9 2,9 2,9 2,9 2,9 7,3 7,3 7,3 12,1 12,1
[Nm]
1,1 1,5
2,25
Tightening torques for
power terminals
[lbf.in]
(10) (13,3)
(20)
Order No.
6SE6440- 2UD31
-1CA1
2UD31
-5DA1
2UD31
-8DA1
2UD32
-2DA1
2UD33
-0EA1
2UD33
-7EA1
2UD34
-5FA1
2UD35
-5FA1
2UD37
-5FA1
Frame Size
C D
E
F
[kW]
11,0 15,0 18,5 22,0 30,0 37,0 45,0 55,0 75,0
Output Rating(CT)
[hp]
15,0 20,0 25,0 30,0 40,0 50,0 60,0 75,0 100,0
Output Power
[kVA]
19,8 24,4 29,0 34,3 47,3 57,2 68,6 83,8 110,5
CT-Input Current 1)
[A]
23,1 33,8 37,0 43,0 59,0 72,0 87,0 104,0 139,0
CT-Output Current
[A]
26,0 32,0 38,0 45,0 62,0 75,0 90,0 110,0 145,0
VT-Input Current 1)
[A]
33,8 37,0 43,0 59,0 72,0 87,0 104,0 139,0 169,0
VT-Output Current
[A]
32,0 38,0 45,0 62,0 75,0 90,0 110,0 145,0 178,0
Fuse [A]
35 50 63 80 100 125 160 200 250
Recommended 3NA
3814 3820 3822 3824 3830 3832 3836 3140 3144
For UL specified
3NE
* 1817-0 1818-0 1820-0 1021-0 1022-0 1224-0
1225-0
1227-0
[mm
2
]
6,0 10,0 10,0 16,0 25,0 25,0 35,0 70,0 95,0
Input Cable, min.
[AWG]
10 8 8 6 3 3 2 2/0
3/0
[mm
2
]
10,0 35,0 35,0 35,0 35,0 35,0 150,0 150,0 150,0
Input Cable, max.
[AWG]
8 2 2 2 2 2 300
300
300
[mm
2
]
6,0 10,0 10,0 16,0 25,0 25,0 35,0 70,0 95,0
Output Cable, min.
[AWG]
10 8 8 6 3 3 2 2/0
3/0
[mm
2
]
10,0 35,0 35,0 35,0 35,0 35,0 150,0 150,0 150,0
Output Cable, max.
[AWG]
8 2 2 2 2 2 300
300
300
[kg]
5,5 16,0 16,0 16,0 20,0 20,0 56,0 56,0 56,0
Weight
[lbs]
12,1 35,0 35,0 35,0 44,0 44,0 123,0 123,0 123,0
[Nm]
2,25 10
50
Tightening torques for
power terminals
[lbf.in]
(20) (89)
(445)
1) Secondary conditions:
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
k
= 2 % referred to the rated drive converter power and a rated line supply voltage
of 400 V without line commutating reactor.
* UL listed fuses such as Class NON from Bussmann are required for use in America