background image

AJ-64 Conveyor Series Technical Manual 7610-003-30-93

Issued: 05-02-2006 Revised: N/A

SECTION 5: PARTS SECTION

60

HEATER ASSEMBLY

Heater Chart

Model

Volts

Phase

KW

Part Number

All*

208

1

10

06401-003-12-94

230

1

10

06401-003-12-95

208

3

10

06401-003-12-94

230

3

10

06401-003-12-95

460

3

10

06401-003-12-96

Heater Chart

Model

KW

208V Models

230V Models

460V Models

All*

15

04540-121-68-45

04540-121-68-46

04540-121-68-47

* - “CS” & “CGP” models do not use electric heaters in the wash tank or power rinse tank.

SERVICE NOTE: When replacing the tub heaters, it is HIGHLY recommended that you also change out the gasket as well.
Once installed, gaskets become compressed and are subjected to extreme temperature changes. Replacing the gasket with a
new one when replacing the heater may prevent future leaks.

SERVICE NOTE: The nuts used to secure the heater to the tub should be torqued to 16 in-lbs. After tightening, the unit should
be allowed to heat up and operate normally for approximately 30 minutes. Secure power to the machine and check the nuts