AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: N/A
SECTION 5: PARTS SECTION
70
RINSE SOLENOID VALVE & VACUUM BREAKER REPAIR PARTS KITS
Complete 110 Volt Solenoid Valve Assembly, 3/4”
04810-100-53-00
Coil & Housing only, 3/4”
04810-200-01-18
Possible Problems:
1. Pilot port extension #1 clogged. Clean hole.
2. Hole #2 Clogged. Pass heated straight pin through hole.
DISASSEMBLY - These valves may be taken apart by
unscrewing the bonnet and the enclosing tube assembly from
the valve body assembly. After unscrewing, carefully lift off the
bonnet and enclosing tube assembly. Don’t drop the plunger.
The o-ring seal and diaphragm cartridge can now be lifted out.
Be careful not to damage the machined faces while the valve
is apart.
TO REASSEMBLE - Place the diaphragm cartridge in the
body with the pilot port extension UP. Hold the plunger with
the synthetic seat against the pilot port. Make sure the o-ring
is in place, then lower the bonnet and enclosing tube assem-
bly over the plunger. Screw the bonnet assembly snugly down
on the body assembly.
Screw
Data Plate
Coil & Housing
Valve Bonnet
Spring
06401-003-07-40
Plunger
06401-003-07-40
Spring position is moved
for clarity.
Goes below the plunger.
O-Ring
06401-003-07-42
Diaphragm
Retainer
Diaphragm
06401-003-07-42
Screen
Retainer
Mesh Screen
Valve Body
Components of
Repair Kit
06401-003-06-24
Cap Screw
Data Plate
Cap
O-Ring
Plunger
Body
Cap Retainer
1
2
Complete Vacuum Breaker Assembly, 3/4” NPT
04820-002-53-77