148
17
CONTROL COMMAND
17
• Command table (continued)
D To send/read memory contents
When sending or reading memory contents, additional code
as follows must be added to appoint the memory channel.
➥Additional code: 0000–0102
(0100=P1, 0101=P2, 0102=Call)
D Band stacking register
To send or read the desired band stacking register ’s con-
tents, combined code of the frequency band and register
codes as follows are used.
For example, when sending/reading the oldest contents in
the 21 MHz band, the code “0703” is used.
• Frequency band code
• Register code
D Codes for memory keyer contents
To send or read the desired memory keyer contents, the
channel and character codes as follows are used.
• Channel code
• Character’s code
1A
050114
Send/read NR level set
(0=0 to 15=15)
050115
Send/read VOX gain (0=0% to
255=100%)
050116
Send/read anti VOX gain (0=0% to
255=100%)
050117
Send/read VOX delay (0=0.0 sec.
to 20=2.0 sec.)
050118
Send/read DTMF speed set
(0=100 msec., 1=200 msec.,
2=300 msec., 3=500 msec.)
050119
Send/read Break-IN delay set
(20=2.0d to 130=13.0d)
06
Send/read SSB transmit band-
width (0=WIDE, 1=MID, 2=NAR)
07
Send/read DSP filter shape
(0= sharp, 1= soft)
08
Send/read manual notch filter1
bandwidth
(0=WIDE, 1=MID, 2=NAR)
09
Send/read manual notch filter2
bandwidth
(0=WIDE, 1=MID, 2=NAR)
0A
Send/read 9600 bps mode set
(0=OFF, 1=ON)
1B
00
Set/read repeater tone frequency
(see p. 149 for details)
01
Set/read TSQL tone frequency
(see p. 149 for details)
02
Set/read DTCS code and polarity
(see p. 149 for details)
1C
00
Set/read the transceiver’s condi-
tion (0=Rx; 1=Tx)
01
Set/read antenna tuner condition
(0=OFF, 1=ON, 2=Start tuning or
while tuning)
Command
Sub command
Description
Code
Frequency band Frequency range (unit: MHz)
01
1.8
1.800000– 1.999999
02
3.5
3.400000– 4.099999
03
7
6.900000– 7.499999
04
10
9.900000–10.499999
05
14
13.900000–14.499999
06
18
17.900000–18.499999
07
21
20.900000–21.499999
08
24
24.400000–25.099999
09
28
28.000000–29.999999
10
50
50.000000–54.000000
11
144
144.000000–148.000000
12
430
430.000000–450.000000
13
GENE
Other than above
Code
Registered number
01
1 (latest)
02
2
03
3 (oldest)
Code
Channel number
01
M1
02
M2
03
M3
04
M4
CW: Clockwise, CCW: Counter Clockwise
Character ASCII code
Description
0–9
30–39
Numerals
A–Z
41–5A
Alphabetical characters
space
20
Word space
/
2F
Symbol
?
3F
Symbol
,
2C
Symbol
.
2E
Symbol
^
5E
e.g., to send
BT
, enter ^4254
✱
2A
Inserts contact number (can be
used for 1 channel only)